News Login | Register | Cart

New From Paradox - Wireless Water Detection

05/07/19

 

 

The WD1 is a two-way wireless water detector designed to trigger an alarm upon contact with water, minimizing the risk of severe water damage from leaks or floods while you are home or away.

Being a two-way device provides an extra level of security and ensures communication to the panel, especially during detection, is received and acknowledged by your system.

The main unit is designed to operate fixed-mounted to a surface (by a center screw), or free-standing, and has a built-in piezo and LED.

The optional ‘Extension Sensor’ ES1 is a useful addition; it acts as an extension of the WD1 detection circuit and is completely waterproof and symmetric (dual-sided detection) with no active components. It allows you to add an additional detection area up to 2m away, and in situations where water submersion is possible, can be placed anywhere while the WD1 main unit is placed in an area safe to transmit the alarm.

Features
Two-way wireless water detector
Tamper on bottom of main unit to notify of unintended movement (fix-mounting required)
433 / 868 MHz selectable dip switch
Blue LED indicator and Piezo
3-year battery life – 1 x AA Alkaline Battery
Any pair of pins in contact with water triggers detection
Can be programmed to shutoff electric water valve using a PGM/2WPGM
Firmware upgradeable
Floor bracket with double-sided tape, no drilling required (included)
ES1 Extension Sensor (optional)
ES1 plug connection and wire cut both supervised

 

Thank you for Choosing


FIRMWARE UPDATES

01/25/19

The global research and development teams at Paradox Security Systems work hard not only to create new and innovative products, but also to improve existing product lines. 

The following list includes recent firmware updates for existing product lines.

A complete update history list is also available at the Paradox website.

Please visit www.paradox.com and login to view/download the firmware updates.

 

Spectra Series SP6000/SP7000 Control Panels – V7.00.012 – On-Site Via Serial Connection or Remotely via IP150/PCS Communication Modules

What's New
•    Added serial lockout for 24hours after 20 invalid codes; it can be unlocked by arming and disarming from the keypad with the master code.
•    Fixed the issue where VDMP3 module didn't stop calling phones after disarm

MG5000/ MG5050 Control Panels – V4.90.006 - On-Site Via Serial Connection or Remotely via IP150/PCS Communication Modules

What's New
•    ECO#S028:
•    Fixed the issue where VDMP3 module didn`t stop calling phones after disarm
•    Added serial lockout for 24hours after 20 invalid codes; it can be unlocked by arming and disarming from the keypad with the master code
•    ECO#S030:
•    Changed RF firmware
•    Fixed signal strength display
•    Fixed the issue where VDMP3 module didn`t stop calling phones after disarm
•    Added serial lockout for 24hours after 20 invalid codes; it can be unlocked by arming and disarming from the keypad with the master code

ACM12 - V4.66.003 – On-Site Via CV4USB cable

What's New
•    Fixed going offline after power-up
•    Fixed arming with exit delay via reader (requires panel 6.85 and up)
•    Arming display on reader shown only if all areas assigned to the door are armed
•    Minor bug fixing

HD78F - V2.03.004 – Remotely Via Insite Gold

What's New
•    Fixed user codes containing digit 0
•    Fixed camera user rights
•    User label not needed anymore to login
•    Added IPRS-7 reporting (Requires new IPRS-7 version to be released)
•    Extended short recording to 30s
•    Minor bug fixing

HD88 - V1.00.027 – Remotely Via Insite Gold

What's New
•    Support for new hardware ECO S080
•    In ECO S080 the opacity of the lens was modified for better day/night operation mode
•    Fixed user codes containing digit 0
•    Fixed camera user rights
•    User label not needed anymore to login
•    Minor bug fixing

IP150 - V4.40.004 – On-Site via InField (Standalone or BabyWare) or Remotely Via Insite Gold

What's New
•    Improved connectivity
•    Added static IP support
•    Added email support
•    Enable/disable SWAN

RTX3 - V6.13 – On-Site Via Serial Connection

What's New
•    This firmware is compatible with the new ECO S034 of RTX3; some hardware components were changed due to end of life.
•    Fixes an issue when if a fail to communicate on bus is reported, the RF doesn't start until power cycle
•    Frequency selectable by jumper (433/868MHz)
•    Removed standalone mode and Esprit compatibility

NV75MX - V1.01.002 – On-Site Via Serial Connection

What's New
•    Fixed zone status not updated correctly
•    Fixed Anti-Mask false alarms




Login in at www.paradox.com
to download and update as directed.

Questions? Call 870-879-2400 for details or for installation support.

 

Thank you for choosing





HOLIDAY HOURS

12/31/18

One of the true joys this holiday season for our team here at Central Security Distribution is the opportunity to say "Thank You" to each and every one of our

dealer partners for the gift of your business and your continued loyalty to us in 2018.

CSD will be closed on Tuesday January 01, 2019. We will reopen for normal business hours on Wednesday January 02, 2019 

We wish you continued success in 2019.  

It has been said that "you cannot go back and make a new start, but you can start again today and make a new ending."

Take a leap of faith and make a new start with Paradox Security Systems and Central Security Distribution.

 

Thank you for choosing


Fianl Days of 2018

12/26/18

This is a short week for most of us, and we just wanted to remind you that we still have a few days left for the sale on security/access control kits.
Stock up and save an additional 5% off of our already reduced kit pricing PLUS any order over $1K qualifies for free shipping. Pricing good until December31st 2018.

Just a note…Paradox has released the following firmware updates and we always recommend you log in and update your Paradox modules to the latest firmware available.

Paradox Firmware Updates Available:

ACM12 - V4.66.003 – On-Site Via CV4USB cable
What's New
•    Fixed going offline after power-up
•    Fixed arming with exit delay via reader (requires panel 6.85 and up)
•    Arming display on reader shown only if all areas assigned to the door are armed
•    Minor bug fixing

HD78F - V2.03.004 – Remotely Via Insite Gold
What's New
•    Fixed user codes containing digit 0
•    Fixed camera user rights
•    User label not needed anymore to login
•    Added IPRS-7 reporting (Requires new IPRS-7 version to be released)
•    Extended short recording to 30s
•    Minor bug fixing

HD88 - V1.00.027 – Remotely Via Insite Gold
What's New
•    Support for new hardware ECO S080
•    In ECO S080 the opacity of the lens was modified for better day/night operation mode
•    Fixed user codes containing digit 0
•    Fixed camera user rights
•    User label not needed anymore to login
•    Minor bug fixing

IP150 - V4.40.004 – On-Site via InField (Standalone or BabyWare) or Remotely Via Insite Gold
What's New
•    Improved connectivity
•    Added static IP support
•    Added email support
•    Enable/disable SWAN

RTX3 - V6.11 – On-Site Via Serial Connection
What's New
•    Fixes an issue when if a fail to communicate on bus is reported, the RF doesn`t start until power cycle

NV75MX - V1.01.002 – On-Site Via Serial Connection
What's New
•    Fixed zone status not updated correctly
•    Fixed Anti-Mask false alarms


Login in at www.paradox.com to download and update as directed..

Questions? Call 870-879-2400 for details or for installation support.

Brad Braley
CSD/Paradox USA
bbraley@buycsd.com
870-879-2400
 

 


HOLIDAY HOURS

12/21/18

CSD / Paradox

One of the real joys in this holiday season for the team here at CSD / Paradox is the amazing opportunity to say thank you to each and every one of you for the gift of your business and your loyalty to us in 2018. 

May our new year together be filled with health, happiness and spectacular success.

CSD / Paradox will be closed December 24th and 25th in 2018

We will re-open for normal business hours on December 26, 2018